The camera table holds the information about the RVS cameras.
[11:24:38] ABILIS_CPX:d p rvs
RES:Rvs-1 ---------------------------------------------------------------------
Run DESCR:
LOG:DS ACT:YES
- IpConf parameters (Read Only) ---------------------------------------
MAC:B8-27-EB-93-FA-DF IPRES:Ip-3
IPADD:192.168.029.101 MASK:255.255.255.000 GW:192.168.029.254
-------+-------------------- Digital Input lines -----------------------
D-IN: | [DESCR:]
-------+----------------------------------------------------------------
-------+-------------------- Digital Output lines ----------------------
D-OUT: | [DESCR:]
| MODE: PULSE-T: PULSE-GAP: START: DFT:
-------+----------------------------------------------------------------
1 | Gate#1
| PULSE 500 250 LAST OFF
-------+-------------------------- Cameras -----------------------------
CAM: | [DESCR:]
ACT: | RESOLUTION: ROTATION: JPEG-QUALITY: EXPOSURE-TIME:
| PREVIEW: HDR: FLASH: METERING:
| SHARPNESS: CONTRAST: BRIGHTNESS: SATURATION:
| LAMP-THRESHOLD: LAMP-DURATION: LAMP-ON-EXPOSURE-TIME:
| STORAGE: REC-MAXAGE: IDLE-REC-INTERVAL:
| MIN-ALARM-DURATION: MAX-ALARM-DURATION:
| ALARM-HOLDOFF: LIVE-REC-DURATION:
-------+----------------------------------------------------------------
Cam-1 | Rvs1_Cam1
YES | 8 0 HIGH AUTO
| MEDIUM YES OFF AVERAGE
| 0 0 0 0
| 0 30 AUTO
| SYS (40 GiB) SYS (14) SYS (2)
| SYS (60) SYS (600)
| SYS (600) SYS (600)
------------------------------------------------------------------------Meaning of the most important parameters:
DESCRResource description. Max 79 chars. Spaces require double quotes (E.g. "str1 str2").
LOGState changes log and alarm generation [NO, D, S, A, L, T, ALL] [+E] (D: Debug Log; S: System Log; A: Alarm view; L: Local audible alarm; T: SNMP traps; +E: Extended Log of state changes, see ref. manual).
ACTOperation activation [NO,
YES].
MACMAC address [00-00-00-00-00-00..FF-FF-FF-FF-FF-FF]. Read Only parameter.
IPRESIP resource [NONE, Ip-1..Ip-250]. Read Only parameter.
IPADDIP address in DDN [0.0.0.0, 0-126.x.x.x, 128-223.x.x.x]. Read Only parameter.
MASKMask in DDN [0.0.0.0, 240.0.0.0 - 255.255.255.255]. Read Only parameter.
GWGateway address in DDN [0.0.0.0, 0-126.x.x.x, 128-223.x.x.x]. Read Only parameter.
D-INDigital Input Line identifier [1..4].
D-OUTDigital Output Line identifier [1..4].
MODEOperational mode [VALUE,
PULSE].
PULSE-TDuration of ON pulse [1..4294967295 ms]. Only for MODE:PULSE.
PULSE-GAPMinimum OFF time after ON pulse [1..65535 ms].
STARTInitial value to be applied when Abilis connects to the
device [LAST, DFT]. If
"LAST" and the last value is unknown or was
lost, the value specified in DFT will be
used.
DFTDefault value to be used when there is not a known and valid value to set [OFF, ON].
CAMCamera identifier [Cam-1..Cam-5 or 1..5]
ACTEnable/disable this camera usage [NO,
YES].
RESOLUTIONResolution [0.3, 1, 2, 5, 8 Mpx].
ROTATIONImage rotation in degrees relative to the camera [0, 90, 180, 270].
JPEG-QUALITYImage compression ratio [LOW,
MEDIUM, HIGH].
EXPOSURE-TIMEExposure time, in fractions of a second [AUTO, 1/8, 1/15, 1/30, 1/60,1/125, 1/200, 1/250, 1/320, 1/400,1/500, 1/1000].
PREVIEWCombined resolution/quality for image preview [LOW, MEDIUM, HIGH] LOW=320x240, MEDIUM=640x480, HIGH=800x600.
HDREnables/disables high dynamic range capture
[NO, YES].
FLASHFlash mode [OFF, AUTO,
ON].
METERINGLight metering mode [AVERAGE,
CENTER, MATRIX,
BACKLIT].
SHARPNESSSharpness [-10..+10].
CONTRASTContrast [-10..+10].
BRIGHTNESSBrightness [-10..+10].
SATURATIONSaturation [-10..+10].
LAMP-THRESHOLDScene brightness threshold for switching on the companion lamp [-10..+10] Only relevant for RVS firmwares that supports companion lamp.
LAMP-DURATIONDuration of companion lamp switch on [10..9000 sec] Only relevant for RVS firmwares that supports companion lamp.
LAMP-ON-EXPOSURE-TIMEExposure time when LAMP is ON, in fraction of a second, [AUTO, 1/8, 1/15, 1/30, 1/60, 1/125, 1/200, 1/250, 1/320, 1/400, 1/500, 1/1000] Only relevant for RVS firmwares that supports companion lamp.
STORAGESize in GiB of the camera storage [SYS, 8..4000 GiB] The
value must be multiple of 4 GiB, or will it be rounded down. When
SYS, the value is taken from
RES:VS configuration.
REC-MAXAGEImages older than this value are deleted [SYS, NOMAX, 0,
1..365 day]. When 0, the recording is disabled. Use is restricted
to LIVE view. When NOMAX, the lifetime is unlimited. Images can be
deleted only manually or due to storage constrains. When
SYS, the value is taken from
RES:VS configuration.
IDLE-REC-INTERVALTime interval between images capture during non-alarm
periods (idle) [SYS, 1..3600 s]. When SYS, the
value is taken from RES:VS
configuration.
MIN-ALARM-DURATIONMinimal duration of high frequency recording when the alarm
condition is detected [SYS, 10..3600 s] It will be extended up to
MAX-ALARM-DURATION if the alarm condition is
detected again during the ALARM-DURATION
period. When SYS, the value is taken from
RES:VS configuration.
MAX-ALARM-DURATIONMaximal duration of an alarm event [SYS, 10..3600 s]. When
SYS, the value is taken from
RES:VS configuration.
ALARM-HOLDOFFIf an alarm is terminated by
MAX-ALARM-DURATION an holdoff is introduced
before the next alarm is allowed [SYS, 0..3600 s]. When
SYS, the value is taken from
RES:VS configuration.
LIVE-REC-DURATIONThe maximum duration of LIVE mode recording [SYS, 10..3600
s]. When SYS, the value is taken from
RES:VS configuration.
![]() | Caution |
|---|---|
To activate the changes, please execute the initialization command init res:rvs |
![]() | Tip |
|---|---|
Interesting chapter: Section 70.20.1.1, “Videorecorder cameras settings”. |
The camera table holds the information about the alarms related to an RVS cameras (up to 16 configurable alarms) .
[15:40:44] ABILIS_CPX:d vs alarm
-------------------------------------------------------------------------------
ID: |[DESCR:]
|ENABLED: |CAM-RES:|CAM: |TRIGGER:|RES: |IO:
|ACTION: |TURN-ON-RES: |TURN-ON-IO:
|TI1: |TI2:
|TI3: |TI4:
|TI5:
-------------------------------------------------------------------------------
0 [Test]
YES Rvs-1 Cam-1 OFF Rvs-1 D-IN-1
NONE #
ALL,00:00-23:59 #
# #
#
-------------------------------------------------------------------------------
Meaning of the most important parameters:
ENABLEDEnable/disable the alarm [NO,
YES].
CAM-RESResource that owns the activated camera [NONE, Rvs-1..Rvs-16].
CAMCamera that will be activated [NONE, Cam-1..Cam-5 or 1..5].
TRIGGERAlarm/event to be monitored [NONE, ON, OFF, *]
RESResource for which the alarm/event is monitored. "#" or "*" or "type-nnn" or "type-*" or the name of a CR (CPX resources) list between single quotes (e.g. * or Gpio-* or Mfio-1 or 'my_res_list').
IOInput/output digital line for which the alarm/event is monitored.
#: None;
D-IN-n, where 'n' can be:
for GPIO Digital IN line, [1..16, *];
for MFIO Digital IN line, [1..7, *];
for RIO Digital IN line, [1..16, *];
for RVS Digital IN line, [1..4, *].
D-OUT-n, where 'n' can be:
for GPIO Digital OUT line, [1..16, *];
for MFIO Digital OUT line, [1..7, *].
for RIO Digital OUT line, [1..16, *];
for RVS Digital OUT line, [1..4, *].
![]() | Caution |
|---|---|
Only for Gpio/MfIo/Rio/Rvs resources. |
ACTIONAction to be executed when the monitored alarm/event occurs
[NONE, MAIL,
SMS, DISA-CB,
TURN-ON-D-OUT]. Values can be joined using ","
operator.
MAIL: Send a mail (SMTP driver must
be properly configured) and MAIL-FROM and
MAIL-TO parameters in VS port should
specify the sender and the recipient of the alarm mail.
SMS: Send a SMS to SMS-CDO number
specified in the VS driver.
DISA-CB: Perform a callback. Using
the DISA-* parameters in VS driver to match the related DISA
service.
TURN-ON-D-OUT]: Turn on a digital
output (i.e. Turning on a light).
TURN-ON-RESThe resource whose output is set in case of alarm.. "#" or "type-nnn", where 'type' can be [Gpio, Mfio, Rio, Rvs].
TURN-ON-IOThe digital output that is set in case of alarm. "#" or "D-OUT-n", where 'n' can be:
for GPIO Digital OUT line, [1..16];
for MFIO Digital OUT line, [1..7].
for RIO Digital OUT line, [1..16, *];
for RVS Digital OUT line, [1..4, *].
![]() | Caution |
|---|---|
Only for |
TI1..TI5Time interval within which the rule is active
[#, ALL,
*, string in format day, hh:mm-hh:mm],
# = disabled (i.e. 'no match'),
ALL and * = always. Value
'day' can be:
a single day of the week [MO, TU, WE, TH, FR, SA, SU];
a set of days of the week (E.g.: MO+TH or TU+TH+SU);
an interval of days of the week (E.g.: MO-WE or TH-SU);
ALL.
![]() | Caution |
|---|---|
To activate the changes, please execute the initialization command init res:vs |
![]() | Tip |
|---|---|
Interesting chapter: Section 70.20.1.2, “Videorecorder alarms settings”. |